A1 Brief

FEATURES
√ Complete type test
√ -40℃-130℃ endure
√ No pores inside of resintrac
√ 100% leakage test
√ Unique physical code for track
√ Top quality worldwide

1. High performance
Daheng epoxy bushings have high application temperature. All Daheng made epoxy bushings have the working temperature range from -40~130℃. It is very important for the transformers which served in very cold area and very hot area. It is also very important especially to the solar/wind generation transformers which usually withstand heavy current in sunshine hot noon and suffer very cold weather in the cold night in those extreme environment, Daheng epoxy bushing had put up very good records.     
Daheng has set up excellent injection equipment to ensure no pores inside the insulation body. Daheng has effective test equipments and test procedure for the epoxy bushings. Each bushing must be tested before it finished in factory.
Daheng has special interface treatment technique (it is said DIT) for the bushing stud surface treatment to ensure the bushing should not leak in long term service.
 
2. Rigorous Test
Daheng epoxy bushings have passed many test, according to IEC60137
● Dielectric Tests
Basic Impulse level test: for 1.2kV class the impulse voltage is 30kV (full wave), and for 2.5kV class, the impulse voltage is 45kV (full wave);
High voltage 50Hz & 60Hz withstand test: for 1.2kV class, test voltage is 10kV/1min., for 2.5kV class, the test voltage is 2.0 kV/ 1min.
● Mechanical Strengthen Tests
Leakage test
Stud push-out test
Stud torque strength test
Cantilever test
Flange torque test
● Environmental test
It includes thermal cycle test. The tested temperature range is -40~130℃, withstand 20 cycles.
All design tests are performed in accordance to the customer’s requirement or on the agreement between Daheng and the customer.  
We have the copies of test report for reference on customer’s request.
We also support customers' specified third party type test report.

Accsessories
Clamp: All bushings supplied with one piece of AL clamp.
Seal gasket: There are seal gaskets which made from NBR & HNBR for customer’s selection. 
 

Series Voltage Class(kV) AC 60 Hz 1 Minute Withstand (kV) BIL and Full Wave Crest(kV) Current Rating(A) *Ex holes *In holes *Ex/In angle Material
ES1230-001 1.2 10 30 800 thread 1 In-line/ rot90 CU
ES1230-002 1.2 10 30 2000 thread 1-2 In-line/ rot90 CU
7B40382X 1.2 10 30 2200 4~20 2 In-line/ rot90 CU
7B40502X 1.2 10 30 3010 4~20 2 In-line/ rot90 CU
2A40752X 2.5 10 45 3150 4~20 4 In-line/ rot90 AL
2B40502X 2.5 10 45 4300 4~20 4 In-line/ rot90 CU
3B40382X 2.5 10 45 2200 4~20 2 In-line/ rot90 CU
3B40502X 2.5 10 45 3300 4~20 2 In-line/ rot90 CU
3B40752X 2.5 10 45 4515 4~20 2 In-line/ rot90 CU
4B40752X 2.5 10 45 4515 4~20 4 In-line/ rot90 CU
5B41002X 2.5 10 45 5400 4~20 4 In-line/ rot90 CU
6B47122X 2.5 10 60 6500 4~20 4 In-line/ rot90 CU
ES5075-003-XX 5 10 75 2200 2~20 2 In-line/ rot90 CU
ES5075-004-XX 5 10 75 1600 2~20 4 In-line/ rot90 AL
ES5075-007-XX 5 10 75 4300 4~20 2 In-line/ rot90 CU
ES5075-008-XX 5 10 75 3000 4~20 2 In-line/ rot90 AL

Current ratings and characteristics are in accordance with IEEE Std C57.12 standard.
*Ex holes is the holes qty of external spade, which is the spade in air for oil-filled transformer
*In holes is the holes qty of internal spade, which is the spade in tank for oil-filled transformer
*Ex/In angle is the angle between external and internal spade of bushing, we can provide in-line and rot 90 for choose. In-line means external and internal spade are in the same angle. Rot90 means two spades are vertical to each other.

Mobile website